张林启,黄培莉,何巧,李淑仪,张静,马立武,彭浩,张汝森.99Tcm-MDP全身骨显像联合SPECT/CT诊断骨外肿瘤[J].中国医学影像技术,2021,37(12):1870~1873
99Tcm-MDP全身骨显像联合SPECT/CT诊断骨外肿瘤
99Tcm-MDP whole-body bone imaging combined with SPECT/CT for diagnosis of extraosseous tumors
投稿时间:2020-10-09  修订日期:2021-10-13
DOI:10.13929/j.issn.1003-3289.2021.12.026
中文关键词:  肿瘤  99m锝美罗酸盐  放射性核素显像  正电子发射断层显像  体层摄影术,X线计算机
英文关键词:neoplasms  technetium Tc 99m medronate  radionuclide imaging  positron-emission tomography  tomography, X-ray computed
基金项目:广州市卫生健康科技项目(20201A011102)。
作者单位E-mail
张林启 广州医科大学附属肿瘤医院核医学科, 广东 广州 510095  
黄培莉 广州医科大学附属肿瘤医院核医学科, 广东 广州 510095  
何巧 中山大学附属第一医院核医学科, 广东 广州 510055  
李淑仪 广州医科大学附属肿瘤医院核医学科, 广东 广州 510095  
张静 广州医科大学附属肿瘤医院核医学科, 广东 广州 510095  
马立武 广州医科大学附属肿瘤医院核医学科, 广东 广州 510095  
彭浩 广州医科大学附属肿瘤医院核医学科, 广东 广州 510095  
张汝森 广州医科大学附属肿瘤医院核医学科, 广东 广州 510095 zhangrusen2015@163.com 
摘要点击次数: 2379
全文下载次数: 543
中文摘要:
      目的 观察99Tcm-亚甲基二磷酸盐(MDP)全身骨显像联合SPECT/CT诊断骨外肿瘤的价值。方法 回顾性分析68例骨外肿瘤患者94处病灶,观察其全身骨显像及SPECT/CT表现,并分析二者联合诊断效能。结果 单纯全身骨显像准确诊断52处骨外肿瘤,准确率55.32%(52/94);其余42处病灶中,35处(35/94,37.23%)因影像学表现与骨骼存在重叠而误诊为转移性骨肿瘤,7处(7/94,7.45%)因病灶99Tcm-MDP摄取低于邻近骨骼而致漏诊。全身骨显像联合SPECT/CT诊断全部94处骨外肿瘤,准确率100%(94/94)。94处病灶中,49处接受病理学检查,其中33处(33/49,67.35%)病灶内见粗大钙化、9处(9/49,18.37%)见细微钙化;CT检出61处(61/94,64.89%)钙化,未显示9处细微钙化。结论 99Tcm-MDP全身骨显像联合SPECT/CT可提高诊断骨外肿瘤的准确性。
英文摘要:
      Objective To observe the value of 99Tcm-labelled methylene diphosphonate (99Tcm-MDP) whole-body bone imaging combining with SPECT/CT for diagnosis of extraosseous tumors. Methods A total of 94 lesions in 68 patients with extraosseous tumors were enrolled. The whole-body bone imaging and SPECT/CT manifestations of lesions were retrospectively analyzed, and the combining diagnostic efficacy was analyzed. Results The accuracy of whole-body bone imaging for diagnosis of extraosseous tumors was 55.32% (52/94). Among the rest 42 lesions, 35 (35/94, 37.23%) were misdiagnosed as metastatic bone tumors due to overlapping imaging findings with bones, while 7 (7/94, 7.45%) were misdiagnosed due to lower uptake of 99Tcm-MDP than adjacent bones. The accuracy of whole-body bone imaging combining with SPECT/CT for diagnosis of extraosseous tumors was 100% (94/94). Pathological examination of 49 lesions were performed, among which coarse calcifications were detected in 33 lesions (33/49, 67.35%) and fine calcifications in 9 (9/49, 18.37%) lesions. CT showed intratumoral calcifications in 61 lesions (61/94, 64.89%), not including the above 9 fine calcifications. Conclusion 99Tcm-MDP whole body bone imaging combining with SPECT/CT could improve the accuracy of diagnosing extraosseous tumors.
查看全文  查看/发表评论  下载PDF阅读器