周建峰,靳勇.Xper-CT与CTPV融合图像在经颈静脉肝内门腔静脉内分流术中的应用[J].中国医学影像技术,2018,34(1):109~112
Xper-CT与CTPV融合图像在经颈静脉肝内门腔静脉内分流术中的应用
Application of fusion imaging combined Xper-CT with CTPV in transjugular intrahepatic portosystemic stent shunt
投稿时间:2017-04-09  修订日期:2017-10-27
DOI:10.13929/j.1003-3289.201704035
中文关键词:  门体分流术,经颈静脉肝内  门静脉造影术  图像融合
英文关键词:Portosystemic shunt,transjugular intrahepatic  Portography  Fusion imaging
基金项目:
作者单位E-mail
周建峰 苏州大学附属第二医院介入放射科, 江苏 苏州 215004  
靳勇 苏州大学附属第二医院介入放射科, 江苏 苏州 215004 jyct@163.com 
摘要点击次数: 2507
全文下载次数: 1057
中文摘要:
      目的 评价利用Xper-CT与CT门静脉造影(CTPV)融合图像作为经颈静脉肝内门腔静脉内分流术(TIPS)中三维路径图的可行性。方法 收集门静脉高压症患者37例,其中21例接受常规TIPS术患者,另16例接受3D路径图下引导TIPS,采集动静脉期和门静脉期图像,对3D路径图下引导TIPS患者在肝脏部位行Xper-CT扫描,在三维工作站中利用"Multi-Modality Matching"功能进行两者图像融合,作为实时透视过程中的三维路径图。结果 Xper-CT与CTPV在融合过程中,骨性对位误差均<2.00 mm;术中门静脉CTPV图像与透视的图像的匹配误差稍大,其中15例上下误差>2.00 mm,1例左右误差>5.00 mm。结论 将Xper-CT与CTPV的融合图像作为TIPS的三维路径图,可在不使用对比剂的情况下,术中多角度观察穿刺针与门静脉的位置关系,提高穿刺的定位准确性和安全性,减少手术时间。
英文摘要:
      Objective To explore the feasibility of fusion image of Xper-CT and CT portal venography (CTPV) as DSA 3D-roadmap in operation of transjugular intrahepatic portosystemic stent shunt (TIPS).Methods Thirty-seven patients with portal hypertension were enrolled in this study, among them 21 underwent conventional TIPS retrospectively, 16 underwent Xper-CT and CTPV imaging to obtain fusion image in the workstation with the software of Multi-Modality Matching for hepatic portal vein without contrast medium administration. Then the fusion image was used as the 3D-roadmap in the process of real-time fluoroscopy.Results In the fusion process of Xper-CT and CTPV, osseous registration error was <2.00 mm, while error of the portal vein fusion image and the real-time X-ray image displacement were >2.00 mm between up and down in 15 patients, >5.00 mm between left and right in 1 patient.Conclusion Xper-CT with CTPV fusion image can be used as 3D-roadmap of TIPS to observe the relationship between puncture needle and the portal vein without administration of contrast medium, improving the accuracy and safety of puncture and reducing operation time.
查看全文  查看/发表评论  下载PDF阅读器