郑立春,欧阳向柳,刘桂超,胡月明,王艳滨,张晓明.剪切波弹性成像与18F-FDG PET/CT显像诊断甲状腺微小癌的对比[J].中国医学影像技术,2017,33(6):868~871
剪切波弹性成像与18F-FDG PET/CT显像诊断甲状腺微小癌的对比
Comparasion of shear wave elastography and 18F-FDG PET/CT imaging in diagnosis of thyroid microcarcinoma
投稿时间:2017-01-02  修订日期:2017-03-04
DOI:10.13929/j.1003-3289.201701004
中文关键词:  超声检查  甲状腺肿瘤  体层摄影术,发射型计算机  体层摄影术,X线计算机
英文关键词:Ultrasonography  Thyroid neoplasms  Tomography, emisson-computed  Tomography, X-ray computed
基金项目:
作者单位E-mail
郑立春 唐山市工人医院核医学科, 河北 唐山 063000  
欧阳向柳 唐山市工人医院超声诊断科, 河北 唐山 063000 usouyangxl@163.com 
刘桂超 唐山市工人医院核医学科, 河北 唐山 063000  
胡月明 唐山市工人医院病理科, 河北 唐山 063000  
王艳滨 唐山市工人医院超声诊断科, 河北 唐山 063000  
张晓明 唐山市工人医院核医学科, 河北 唐山 063000  
摘要点击次数: 3234
全文下载次数: 1172
中文摘要:
      目的 比较剪切波弹性成像与18F-FDGPET/CT显像诊断甲状腺微小癌的价值。方法 回顾性分析经病理证实的甲状腺小结节患者超声剪切波弹性成像及18F-FDGPET/CT显像资料,计算并比较2种方法诊断甲状腺微小癌的灵敏度、特异度、准确率、阳性预测值及阴性预测值。结果 48个甲状腺小结节中,37个为恶性结节,11个为良性结节,剪切波弹性成像与18F-FDGPET/CT显像诊断甲状腺微小癌的灵敏度、特异度、准确率、阳性预测值及阴性预测值结果分别为91.89%(34/37)、81.82%(9/11)、89.58%(43/48)、94.44%(34/36)、75.00%(9/12)和29.73%(11/37)、72.73%(8/11)、39.58%(19/48)、78.57%(11/14)、23.53%(8/34);两种方法的灵敏度、准确率及阴性预测值差异有统计学意义(P均<0.05),特异度、阳性预测值差异无统计学意义(P均>0.05)。结论 剪切波弹性成像对甲状腺微小癌的诊断价值优于18F-FDGPET/CT。
英文摘要:
      Objective To compare the diagnostic value of shear wave elastography and 18F-FDG PET/CT imaging in diagnosis of thyroid microcarcinoma. Methods Shear wave elastography and 18F-FDG PET/CT data of patients with thyroid nodules confirmed by pathology were analyzed retrospectively. The sensitivity, specificity, accuracy, positive and negative predictive value of the two methods in diagnosis of malignant thyroid micronodules were compared. Results In all of the 48 micronodules, 37 were malignant, 11 were benign. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of shear wave elastography and 18F-FDG PET/CT were 91.89% (34/37), 81.82% (9/11), 89.58% (43/48), 94.44% (34/36), 75.00% (9/12) and 29.73% (11/37), 72.73% (8/11), 39.58% (19/48), 78.57% (11/14), 23.53% (8/34), respectively. The sensitivity, accuracy and negative predictive value between the two methods had statistical difference (all P<0.05), and the specificity and positive predictive value between the two methods had no statistical difference (both P>0.05). Conclusion Compared to 18F-FDG PET/CT imaging, the diagnositic value of shear wave elastography in diagnosis of thyroid microcarcinoma has obvious advantages.
查看全文  查看/发表评论  下载PDF阅读器