孙利飞,董越,陈靖,刘爱连,程凡容,蔡宁,王茹欣,刘义军.能谱CT基物质成像评估卵巢切除术后患者腰椎钙(水)密度[J].中国医学影像技术,2015,31(3):454~457
能谱CT基物质成像评估卵巢切除术后患者腰椎钙(水)密度
Material decomposition images of spectral CT evaluation of calcium (water) density of lumbar vertebrae in women with ovariectomy
投稿时间:2014-08-08  修订日期:2014-12-05
DOI:10.13929/j.1003-3289.2015.03.038
中文关键词:  卵巢切除术  基物质成像  腰椎  体层摄影术,X线计算机
英文关键词:Ovariectomy  Material decomposition images  Lumbar vertebrae  Tomography, X-ray computed
基金项目:大连科技局2013科学计划项目(2013E15SF165)。
作者单位E-mail
孙利飞 大连医科大学附属第一医院放射科, 辽宁 大连 116011  
董越 大连医科大学附属第一医院放射科, 辽宁 大连 116011 dyy1026@sina.com 
陈靖 大连医科大学附属第一医院放射科, 辽宁 大连 116011  
刘爱连 大连医科大学附属第一医院放射科, 辽宁 大连 116011  
程凡容 大连医科大学附属第一医院放射科, 辽宁 大连 116011  
蔡宁 大连医科大学附属第一医院放射科, 辽宁 大连 116011  
王茹欣 大连医科大学附属第一医院放射科, 辽宁 大连 116011  
刘义军 大连医科大学附属第一医院放射科, 辽宁 大连 116011  
摘要点击次数: 2205
全文下载次数: 812
中文摘要:
      目的 应用能谱CT基物质成像技术评价卵巢切除术后腰椎钙(水)密度变化特征。方法 对29例50~60岁卵巢切除术后患者(卵巢切除组,手术≤1年11例、手术>1年18例)及31例同年龄段绝经后患者(对照组)进行腹部能谱CT检查。由2名放射科医师测量L1~3椎体中心层面的钙(水)密度,分析2名医师测量结果的一致性、腰椎不同位置钙(水)密度的组内差异及两组间钙(水)密度差异。结果 2名医师的测量结果具有一致性(组内相关系数0.97~0.99);卵巢切除术后组、对照组的L1、2、3椎体相邻椎体间的钙(水)密度差异无统计学意义(P均>0.05);卵巢切除术后≤1年和>1年患者腰椎的钙(水)密度间差异无统计学意义(P>0.05),但均低于对照组,差异有统计学意义(P<0.05);卵巢切除术后患者腰椎的钙(水)密度较对照组下降约15%。结论 CT能谱成像对卵巢切除术后腰椎钙(水)密度监测具有一定意义,卵巢切除可使绝经后女性腰椎的钙(水)密度进一步下降。
英文摘要:
      Objective To assess lumbar calcium (water) density with material decomposition images of spectral CT in patients with ovariectomy. Methods Twenty-nine patients with ovariectomy (ovarieclomy group, 11 patients with ovariectomy ≤1 year, 18 patients with ovariectomy >1 year) and 31 postmenopausal patients (control group) were included. All patients underwent abdominal spectral CT examination. Two experienced radiologists independently measured the density calcium-water and interobserver agreement were analyzed. Mean DCa(Wa) values of the two groups and the mean DCa(Wa) values of adjacent lumbar vertebra were compared. Results DCa(Wa) values of interobserver were perfect agreement (ICC 0.97—0.99), the DCa(Wa) between L1 and L2, L2 and L3 had no significant difference in the two groups (P>0.05).The DCa(Wa) between patients with ovariectomy ≤1 year and the patients with ovariectomy >1 year had no significant difference (P>0.05), but all were lower than control group (P<0.05), the DCa(Wa) of L1—3 vertebral body showed significant drops in patients with ovariectomy. Conclusion The calcium and water-based material decomposition images of spectral CT are useful to evaluate the lumbar calcium (water) density changes in the patients with ovariectomy, and ovariectomy may further reduce lumbar calcium (water) density.