林敏,黄丹凤,陈志奎,林礼务,薛恩生,何以敉,黄嵘森,林鹏.自制高分子微泡超声造影机械指数与频率和峰值强度的相关性[J].中国医学影像技术,2014,30(6):805~808
自制高分子微泡超声造影机械指数与频率和峰值强度的相关性
Correlation between mechanical index and frequency with peak intensity in contrast-enhanced ultrasound with self-made polymer acoustic contrast agents
投稿时间:2014-03-06  修订日期:2014-04-21
DOI:
中文关键词:  超声检查  造影剂  机械指数  超声频率
英文关键词:Ultrasonography  Contrast media  Mechanical index  Ultrasonic frequency
基金项目:全国大学生创新创业训练计划项目(201310392022)。
作者单位E-mail
林敏 福建医科大学附属协和医院超声科, 福建 福州 350001  
黄丹凤 福建医科大学附属协和医院超声科, 福建 福州 350001  
陈志奎 福建医科大学附属协和医院超声科, 福建 福州 350001 jimchen2003@163.com 
林礼务 福建医科大学附属协和医院超声科, 福建 福州 350001  
薛恩生 福建医科大学附属协和医院超声科, 福建 福州 350001  
何以敉 福建医科大学附属协和医院超声科, 福建 福州 350001  
黄嵘森 福建医科大学医学技术与工程学院影像系, 福建 福州 350001  
林鹏 福建医科大学医学技术与工程学院影像系, 福建 福州 350001  
摘要点击次数: 3423
全文下载次数: 1448
中文摘要:
      目的 探讨兔体内自制高分子微泡CEUS机械指数和频率与峰值强度的相关性。方法 采用单乳化法制备包裹全氟戊烷的嵌段共聚物微泡造影剂,固定其他超声扫描条件,对6只新西兰大白兔于机械指数0.04、0.09、0.17、0.34和超声频率3.5、5.0、6.5、8.0 MHz下进行肾脏CEUS,分析机械指数和频率与峰值强度的相关性;静脉注射10倍造影剂量微泡,观察毒性反应。结果 自制微泡平均粒径为(3.92±1.43)μm。兔体内峰值强度与机械指数呈正相关(r=0.99,P<0.05),与超声频率呈负相关(r=-0.93,P<0.05);静脉注射大剂量微泡后,未见明显毒性反应。结论 采用自制高分子微泡作为造影剂对兔进行CEUS时,峰值强度与机械指数呈正相关,与超声频率呈负相关;微泡安全性良好。
英文摘要:
      Objective To explore correlation between mechanical index and frequency with peak intensity in CEUS of rabbit kidney with self-made polymer microbubbles as contrast agents. Methods The diblock copolymer microbubbles encapsulating perfluoropentane were prepared with single emulsification method. CEUS was performed with mechanical index of 0.04, 0.09, 0.17, 0.34 and frequency of 3.5, 5.0, 6.5, 8.0 MHz, respectively, with the other condition being unchanged. The correlation between mechanical index and frequency with peak intensity were analyzed. The toxicity reactions of the animals were observed after intravenous injection of microbubbles of ten-fold dose for CEUS. Results The mean diameter of the self-made microbubbles was (3.92±1.43)μm. The peak intensity was positively correlated with peak intensity (r=0.99, P<0.05) and negatively correlated with ultrasonic frequency (r=-0.93, P<0.05). After intravenous injection of large dose microbubbles, no obvious toxicity reaction was found in all the animals. Conclusion The peak intensity has positive correlation with mechanical index and negative correlation with frequency in CEUS of rabbit kidney using self-made polymer acoustic contrast agents that have great safety.