夏巍,尹肖睿,吴晶涛,吴海涛.探讨合理化的多层螺旋CT肺动脉造影技术[J].中国医学影像技术,2012,28(10):1914~1917
探讨合理化的多层螺旋CT肺动脉造影技术
Rationalization of multi-slice spiral CT pulmonary angiography technology
投稿时间:2012-04-28  修订日期:2012-06-22
DOI:
中文关键词:  肺栓塞  体层摄影术,X线计算机  监测阈值  呼吸模式
英文关键词:Pulmonary embolism  Tomography, X-ray computed  Monitor threshold  Respiratory pattern
基金项目:
作者单位E-mail
夏巍 扬州大学临床医学院 江苏省苏北人民医院影像科, 江苏 扬州 225001  
尹肖睿 扬州大学临床医学院 江苏省苏北人民医院影像科, 江苏 扬州 225001 yinxiaorui1@sina.com 
吴晶涛 扬州大学临床医学院 江苏省苏北人民医院影像科, 江苏 扬州 225001  
吴海涛 扬州大学临床医学院 江苏省苏北人民医院影像科, 江苏 扬州 225001  
摘要点击次数: 2547
全文下载次数: 819
中文摘要:
      目的 观察多层螺旋CT肺动脉造影(MSCTPA)在不同扫描参数及呼吸模式下的肺动脉强化程度,探讨获得最佳图像质量的合理化技术。方法 前瞻性选择90例接受MSCTPA检查的PE患者,将其随机均分成Ⅰ、Ⅱ、Ⅲ组,分别设定50、80、120 HU作为监测阈值进行追踪触发扫描;将每组再随机均分为A、B两亚组,分别于平静呼吸状态下进行扫描或吸气后屏气进行扫描,比较肺动脉、肺静脉、主动脉强化CT值及不同组别MSCTPA的重建图像质量。结果 Ⅰ、Ⅱ、Ⅲ组肺动脉CT值分别为(488.12±17.21)HU、(344.53±10.43)HU、(181.95±24.13)HU(P<0.05);肺静脉CT值分别为(92.26±16.76)HU、(210.57±18.28)HU、(320.82±26.25)HU(P<0.05);主动脉CT值分别为(128.48±20.36)HU、(280.35±25.56)HU、(402.75±32.64)HU(P<0.05)。ⅠA、ⅠB亚组肺动脉干CT值分别为(502.28±9.34)HU、(474.94±11.78)HU(P=0.446);ⅡA、ⅡB组肺动脉干CT值分别为(352.47±8.16)HU、(336.38±6.46)HU(P=0.034);ⅢA、ⅢB组肺动脉干CT值分别为(197.32±7.34)HU、(165.78±24.67)HU(P=0.005)。Ⅰ、Ⅱ、Ⅲ各组图像质量评分均值分别为3.97、3.43、2.60分。结论 MSCTPA中,设定50 HU为监测阈值,于平静呼吸下行追踪触发扫描,可获得最佳图像质量。
英文摘要:
      Objective To compare the enhancement degree of pulmonary artery of multi-slice spiral CT pulmonary angiography (MSCTPA) with different scanning parameters and breathing patterns, in order to obtain the best image quality.Methods Ninety patients of PE who underwent MSCTPA were prospectively selected and randomly divided into group Ⅰ, Ⅱ and Ⅲ, in which 50, 80 and 120 HU were taken as the monitoring threshold tracking triggers, respectively. Patients in each group were divided in to two subgroups and receiving calm breathing scanning (subgroup A) or air suction after breath-hold scanning (subgroup B). Enhancement of pulmonary artery, pulmonary vein and aorta, as well as reconstructed image quality of MSCTPA were compared. Results CT value of the pulmonary artery in group Ⅰ, Ⅱ and Ⅲ was (488.12±17.21)HU, (344.53±10.43)HU and (181.95±24.13)HU, respectively (P<0.05), of the pulmonary vein was (92.26±16.76)HU, (210.57±18.28)HU and (320.82±26.25)HU, respectively (P<0.05), while of aorta was (128.48±20.36)HU, (280.35±25.56)HU and (402.75±32.64)HU, respectively (P<0.05). CT value was (502.28±9.34)HU and (474.94±11.78)HU in ⅠA and ⅠB subgroup (P=0.446), (352.47±8.16)HU and (336.38±6.46)HU in ⅡA and ⅡB subgroup (P=0.034), (197.32±7.34)HU and (165.78±24.67)HU in ⅢA and ⅢB subgroup (P= 0.005). The average score of image quality was 3.97, 3.43 and 2.60 in groupⅠ, Ⅱ and Ⅲ, respectively. Conclusion Taking 50 HU as the monitor threshold, quiet breathing and down-track triggering scanning enables the best MSCTPA image quality.
查看全文  查看/发表评论  下载PDF阅读器