齐燕,陈楠,王星,杨方,张莉,彭光明,卓彦,陈霖,欧陕兴,李坤成.高分辨率MR测量国人正常成年男性视神经长度[J].中国医学影像技术,2010,26(5):840~843 |
高分辨率MR测量国人正常成年男性视神经长度 |
Measurement of the length of optic nerve in normal adult male Chinese with high-resolution MR |
投稿时间:2009-11-19 修订日期:2010-02-02 |
DOI: |
中文关键词: 视神经 磁共振成像 成像,三维 |
英文关键词: Optic nerve Magnetic resonance imaging Imaging, three-dimensional |
基金项目:863计划资助项目(2006AA02z391)、科技部基金项目(2005CB522800、2004CB318101)、国家自然科学基金资助项目(30621004)。 |
作者 | 单位 | E-mail | 齐燕 | 广州军区广州总医院放射科,广东 广州 510010 | | 陈楠 | 首都医科大学附属宣武医院放射科,北京 100053 | | 王星 | 首都医科大学附属宣武医院放射科,北京 100053 | | 杨方 | 广州军区广州总医院放射科,广东 广州 510010 | | 张莉 | 广州军区广州总医院放射科,广东 广州 510010 | | 彭光明 | 广州军区广州总医院放射科,广东 广州 510010 | | 卓彦 | 中国科学院生物物理研究所脑与认知科学国家重点实验室,北京 100101 | | 陈霖 | 中国科学院生物物理研究所脑与认知科学国家重点实验室,北京 100101 | | 欧陕兴 | 广州军区广州总医院放射科,广东 广州 510010 | oushanxing@sina.com | 李坤成 | 首都医科大学附属宣武医院放射科,北京 100053 | |
|
摘要点击次数: 2919 |
全文下载次数: 881 |
中文摘要: |
目的 观察高分辨率MRI平行于视神经的轴位及斜矢状位重建测量国人正常成年男性视神经长度的差异。 方法 对500例无视力障碍的中国成年男性志愿者行全脑T1加权三维磁化强度预备梯度回波序列扫描。采用Aquariusws软件重建轴位及斜矢状位MR图像,测量各段视神经长度,比较两种重建方法的差异性。 结果 平行于视神经的轴位及斜矢状位MRI均可清晰显示视神经的结构。轴位测量视神经全长为(43.58±3.41)mm,斜矢状位为(42.13±3.26)mm,轴位测量值大于斜矢状位(P<0.05)。 结论 高分辨率MRI可清晰显示视神经整体轮廓,准确测量视神经长度,平行于视神经的轴位重建是测量视神经长度的最佳方法之一。 |
英文摘要: |
Objective To compare the difference of the length of optic nerve in normal adult male Chinese measured on axial or oblique sagittal reconstruction with high-resolution MRI. Methods Totally 500 adult male Chinese without visual dysfunction underwent brain MR scan with T1 weighted three-dimensional magnetization-prepared rapid acquisition gradient-echo sequence. The reconstructed images of axial and oblique sagittal section parallel with optic nerve were obtained with Aquariusws 3D analysis software. The length of the optic nerve was measured on both axial and oblique sagittal images, and the difference between the two methods was studied. Results The anatomy of the optic nerve could be clearly displayed on both axial and oblique sagittal images. The full length of optic nerve was (43.58±3.41) mm on axial image and (42.13±3.26) mm on oblique sagittal image. The measured value of axial image was higher than that of oblique sagittal image (P<0.05). Conclusion High-resolution MRI can well display the optic nerve, while axial reconstruction is one of the best ways to measure the length of optic nerve. |