崔燕海,黄美萍,梁长虹,刘辉,周涛,刘其顺.64层螺旋CT冠脉CTA对比剂注射方案优化[J].中国医学影像技术,2008,24(3):374~377
64层螺旋CT冠脉CTA对比剂注射方案优化
The optimization of contrast media injection protocol in heart coronary CTA by 64-MSCT
投稿时间:2007-09-19  修订日期:2008-01-12
DOI:
中文关键词:  冠状动脉  对比剂  体层摄影术,X线计算机
英文关键词:Coronary artery  Contrast media  Tomography, X-ray computed
基金项目:广东省科技攻关项目(2006B36030026),广州省科技攻关项目(2006Z3-E0241)。
作者单位E-mail
崔燕海 广东省人民医院放射科,广东 广州 510080  
黄美萍 广东省人民医院放射科,广东 广州 510080  
梁长虹 广东省人民医院放射科,广东 广州 510080 cjr.lchh@vip.163.com 
刘辉 广东省人民医院放射科,广东 广州 510080  
周涛 广东省人民医院放射科,广东 广州 510080  
刘其顺 广东省人民医院放射科,广东 广州 510080  
摘要点击次数: 3406
全文下载次数: 1122
中文摘要:
      目的 比较相同碘负荷情况下,不同对比剂注射方案以及相同碘浓度情况下,不同对比剂注射流率在64层螺旋CT冠脉CTA的应用效果。 方法 58例可疑冠心病病例分为3组,分别采用不同对比剂注射方案进行冠脉CTA检查;对血管强化程度、重建血管清晰度进行评价。 结果 300 mgI/ml×5 ml/s和370 mgI/ml×4 ml/s 两种注射方案冠脉平均强化水平相似,约350~370 HU,两者差异不具有统计学意义。370 mgI/ml×4 ml/s和370 mgI/ml×3 ml/s两种注射方案在升主动脉,左、右冠状动脉主干平均强化程度分别为360 HU左右和330 HU左右,但两组间的差异不具有统计学意义,两组重建血管清晰度无统计学差异,96.3%的重建血管能够满足诊断。 结论 应用370 mgI/ml×3 ml/s注射方案相当的单位时间碘负荷量,平均强化程度330 HU,能够满足64层螺旋CT冠脉CTA检查。
英文摘要:
      Objective To compare the enhancement of coronary arteries and the quality of reconstruction images using different contrast materials (CM) injection protocols on 64-multidetector computed tomography (64-MSCT) coronary angiography. Methods Fifty-eight patients were divided into three groups and underwent coronary artery CTA with three different injection protocols, respectively: group 1: 300 mgI/m×5 ml/s, 60-80 ml CM+50 ml saline, group 2: 370 mgI/ml×4 ml/s, 65-75 ml CM, group 3: 370 mgI/ml×3 ml/s, 65-75 ml CM. The enhancement of coronary arteries and the definition of the reconstructed vessels were evaluated, respectively. Results The mean degree of enhancement of coronary arteries were similar (about 350-370 HU) in group 1 and group 2. The difference between the two groups was insignificant. The mean degree of enhancement of coronary arteries in group 2 (about 360 HU) was higher than that in group 3 (about 330 HU). However, there was no significant difference between them. The quality of reconstruction images between group 2 and group 3 were equal, too. 96.3% of images were adequate for diagnostic need. Conclusion The enhancement of coronary arteries is similar using different CM injection protocols with the same time-iodine loading dose of 370 mgI/ml×3 ml/s. The enhancement of 330 HU is competent for diagnosing coronary artery disease.
查看全文  查看/发表评论  下载PDF阅读器