中文摘要: |
目的 探讨仿真直肠排粪造影在直肠前突排粪造影检查中的应用价值。方法 对88例疑似直肠前突患者随机进行分组,分别行仿真直肠排粪造影(试验组)和传统直肠排粪造影(对照组)检查,且对16例自愿者进行了两种方法的对比检查。 结果 按照卢任华测量方法将两组所得数据进行比较,发现应用组检查阳性率和检出病变的严重程度均高于对照组。 结论 仿真直肠排粪造影在检出病变的有无及发现病变的严重程度等方面较传统排粪造影有明显的优越性。 |
英文摘要: |
Objective To analyses the value of the simulation defecography used in the diagnosis of rectocele. Methods Eighty-eight cases diagnosed as suspect rectocele were divided into two groups, the testing group were examined by the similation defecography and the comparison group were examined by the traditional defecography, and the two Methods have also been carried on 16 volunteers for comparison. Results According to Lu Renhua methods, the datas of two groups was comparsed, the testing group discovered rate and the pathological theserious degree to be higher than the comparison group. Conclusion Whether discovered rate or the pathological theserious degree, the similation defecography is superiority to the traditional defecography. |