童清平,罗福成,马鹏天.高频探头对白内障声像图分型的探讨[J].中国医学影像技术,1994,10(4):262~264 |
高频探头对白内障声像图分型的探讨 |
Study on Sonographic Patterns of Cataract by 10MHz High Frequency Probe |
|
DOI: |
中文关键词: 高频探头 白内障 声像图分型 |
英文关键词:High frequency probe Cataract Sonographic patterns |
基金项目: |
|
摘要点击次数: 1467 |
全文下载次数: 488 |
中文摘要: |
本文应用10MHz高频探头检测28例48眼白内障患者,经临床特殊检查和手术病理证实。B超检出44眼,总符合率为91.7%(44/48).44眼晶体声像图表现可分为三型:皮质型、核型和完全型(混合型).B超对核型和完全型(混合型)诊断符合率为100%,皮质型有4例假阴性(11%).本文对各型声像图表现及假阴性作了研究与探讨。 |
英文摘要: |
Using 10MHz high Frequency probe,48 cataract eyes of 28cases were examined,all cases were confirmed by special clinical examines operation and pathology.The accuracy of sonography diagnosis was 91.7%.The ultrasaund appearences of lens were classified into three patterns:cortical,nuclear and complete(mixed).Both the accuracy of nuclear and complete cataract were 100%,that of cortical was 89%,4 cases of cortical being false negative,All patterns of cataract sonography were studies and false negative results of sonography were analysed and discussed. |
查看全文 查看/发表评论 下载PDF阅读器 |
|
|
|