童清平,罗福成,马鹏天.高频探头对白内障声像图分型的探讨[J].中国医学影像技术,1994,10(4):262~264
高频探头对白内障声像图分型的探讨
Study on Sonographic Patterns of Cataract by 10MHz High Frequency Probe
  
DOI:
中文关键词:  高频探头  白内障  声像图分型
英文关键词:High  frequency  probe  Cataract  Sonographic  patterns
基金项目:
作者单位
童清平 The 105th Hospital of PLA 
罗福成 The 105th Hospital of PLA 
马鹏天 The 105th Hospital of PLA 
摘要点击次数: 1467
全文下载次数: 488
中文摘要:
      本文应用10MHz高频探头检测28例48眼白内障患者,经临床特殊检查和手术病理证实。B超检出44眼,总符合率为91.7%(44/48).44眼晶体声像图表现可分为三型:皮质型、核型和完全型(混合型).B超对核型和完全型(混合型)诊断符合率为100%,皮质型有4例假阴性(11%).本文对各型声像图表现及假阴性作了研究与探讨。
英文摘要:
      Using 10MHz high Frequency probe,48 cataract eyes of 28cases were examined,all cases were confirmed by special clinical examines operation and pathology.The accuracy of sonography diagnosis was 91.7%.The ultrasaund appearences of lens were classified into three patterns:cortical,nuclear and complete(mixed).Both the accuracy of nuclear and complete cataract were 100%,that of cortical was 89%,4 cases of cortical being false negative,All patterns of cataract sonography were studies and false negative results of sonography were analysed and discussed.