吕发金,谢鹏,罗天友,张志伟,何怡红,孙晓川,牟君,方维东.数字减影CT血管成像在蛛网膜下腔出血诊断中的价值[J].中国医学影像技术,2007,23(1):45~48
数字减影CT血管成像在蛛网膜下腔出血诊断中的价值
Value of digital subtraction CT angiography in subarachnoid hemorrhage
投稿时间:2006-08-19  修订日期:2006-12-27
DOI:
中文关键词:  蛛网膜下腔出血  动脉瘤  体层摄影术,X线计算机  血管造影术
英文关键词:Subarachnoid hemorrhage  Aneurysm  Tomography, X-ray computed  Angiography
基金项目:
作者单位E-mail
吕发金 重庆医科大学附属第一医院放射科,重庆 400016 xiepeng58@21cn.com 
谢鹏 重庆医科大学附属第一医院神经内科,重庆 400016  
罗天友 重庆医科大学附属第一医院放射科,重庆 400016  
张志伟 重庆医科大学附属第一医院放射科,重庆 400016  
何怡红 重庆医科大学附属第一医院放射科,重庆 400016  
孙晓川 重庆医科大学附属第一医院神经外科,重庆 400016  
牟君 重庆医科大学附属第一医院神经内科,重庆 400016  
方维东 重庆医科大学附属第一医院放射科,重庆 400016  
摘要点击次数: 17653
全文下载次数: 4650
中文摘要:
      目的 探讨数字减影CT血管成像(DSCTA)在蛛网膜下腔出血(SH)诊断中的应用价值。方法 分析72例经DSA和(或)手术确诊为动脉瘤的SH患者的CTA资料,比较常规CTA和数字减影CTA的三维容积再现(3D VR)图像重建的图像质量、重建使用时间、检出动脉瘤的大小、敏感性和特异性。结果 本组72例88个动脉瘤,DSCTA检出动脉瘤的敏感性和特异性为100%,常规CTA检出动脉瘤的敏感性为89.8%,特异性为100%;DSCTA与常规CTA检出动脉瘤的大小无显著性差异;DSCTA可检出全部床突下与颅骨紧贴的动脉瘤,图像信噪比略下降,但增加了血管对比度,图像重建时间无显著性增加。结论 DSCTA同常规CTA相比是一种快速、易行和可靠的CTA技术,使血管对比度明显增加,有利于床突下动脉瘤的检出。DSCTA可作为检出动脉瘤的首选检查方法,避免有创的DSA检查。
英文摘要:
      Objective To evaluate the diagnostic value of digital subtraction CT angiography (DSCTA) in subarachnoid hemorrhage (SH). Methods The CT angiographic data of 72 aneurysms patients with SH diagnosed by DSA and/or surgery were analyzed. With DSCTA, the image quality, time of reconstruction, size of aneurysms, sensitivity and specificity in aneurysms detection in 3D volume rendering (3D VR) were compared with conventional CTA. Results Eighty-eight aneurysms were detected in 72 patients by DSCTA, with 100% sensitivity and specificity, while only 89.8% and 100% respectively with conventional CTA. There was no significant difference in the display of aneurysms size and consumption of postprocessing time. All aneurysms near cranial bottom could be successfully detected by DSCTA, with slightly decreased image signal to noise ratio and improved vessel contract. There was no significantly increase in postprocessing time. Conclusion Compare with conventional CTA, DSCTA is a fast, easy and reliable techniques, improved contrast of vessel with slightly reduce in image quality. DSCTA is a primary choice for aneurysm detection in SH, to avoid invasive DSA.