郭睿,胡跃群,胡鹏志,梁友发,何海波,冯智超,谭伏平,王维.头颈部CTA联合全脑CT灌注一站式扫描中时间间隔对灌注参数的影响[J].中国医学影像技术,2019,35(7):1095~1098
头颈部CTA联合全脑CT灌注一站式扫描中时间间隔对灌注参数的影响
Impact of time interval on perfusion parameters in head and neck CTA combined with whole brain CT perfusion one-stop scanning
投稿时间:2018-12-11  修订日期:2019-05-30
DOI:10.13929/j.1003-3289.201812061
中文关键词:  体层摄影术,X线计算机    灌流  血管造影术
英文关键词:tomography, X-ray computed  brain  perfusion  angiography
基金项目:
作者单位E-mail
郭睿 中南大学湘雅三医院放射科, 湖南 长沙 410013  
胡跃群 中南大学湘雅三医院放射科, 湖南 长沙 410013 huyuequn@126.com 
胡鹏志 中南大学湘雅三医院放射科, 湖南 长沙 410013  
梁友发 中南大学湘雅三医院放射科, 湖南 长沙 410013  
何海波 中南大学湘雅三医院放射科, 湖南 长沙 410013  
冯智超 中南大学湘雅三医院放射科, 湖南 长沙 410013  
谭伏平 中南大学湘雅三医院放射科, 湖南 长沙 410013  
王维 中南大学湘雅三医院放射科, 湖南 长沙 410013  
摘要点击次数: 2287
全文下载次数: 688
中文摘要:
      目的 探讨头颈部CTA联合全脑CT灌注(CTP)一站式扫描中,时间间隔对灌注参数的影响。方法 回顾性分析60例急性脑缺血症状患者的标准脑CTP图像(标准组),于颅脑CTP图像中将动脉峰值期前后各1组扫描数据剔除,使得其前后间隔时间增加至4.5 s,模拟头颈部CTA联合全脑CTP一站式扫描(模拟组)。计算标准组与模拟组灌注参数[脑血流量(CBF)、脑血容量(CBV)、平均通过时间(MTT)]绝对百分比误差值,并分析脑灰质左侧与右侧、白质左侧与右侧灌注参数比值(rCBF、rCBV、rMTT)的相关性。结果 基底核层面CBF、CBV、MTT的绝对百分比误差值均值均<10%。灰质左侧与右侧rCBF(r=0.988,P<0.001)、rCBV(r=0.963,P<0.001)、rMTT(r=0.983,P<0.001)均呈正相关,白质左侧与右侧rCBF(r=0.980,P<0.001)、rCBV(r=0.957,P<0.001)、rMTT(r=0.986,P<0.001)均呈正相关。结论 头颈部CTA联合全脑CTP一站式扫描中时间间隔对灌注参数的影响较小。
英文摘要:
      Objective To explore the impact of time interval on perfusion parameters in head-neck CTA combined with one-stop scanning whole brain CT perfusion (CTP).Methods Standard brain CTP data of 60 patients with acute cerebral ischemic stroke were analyzed retrospectively (standard group). On the brain CTP images of standard group, one group of scanning data were removed before and after the peak period of the artery, and the interval between the anterior and posterior intervals increased to 4.5 s. Head and neck CTA combined with whole brain CTP one-stop scanning was simulated (simulation group). The mean absolute percentage error of perfusion parameters (cerebral blood flow[CBF], cerebral blood volume[CBV] and mean transit time[MTT]) between the standard group and the simulated group was calculated, and the correlation of perfusion parameter ratio (rCBF, rCBV, rMTT) between right and left gray matter, right and left white matter were analyzed.Results The absolute percentage errors of basal nucleus CBF, CBV and MTT were all less than 10%. There was positive correlation of gray matter left and right rCBF (r=0.988, P<0.001), rCBV (r=0.963, P<0.001) and rMTT (r=0.983, P<0.001), also of white matter left and right rCBF (r=0.980, P<0.001), rCBV (r=0.957, P<0.001) and rMTT (r=0.986, P<0.001).Conclusion The time interval between head-neck CTA combined with one-stop scanning whole brain CTP has little impact on perfusion parameters.
查看全文  查看/发表评论  下载PDF阅读器