郝振亮,王俊清,任超,赵晓斌.静脉注射18F-FDG注射液后冲洗注射器对残留剂量及肝脏标准化摄取值的影响[J].中国医学影像技术,2019,35(7):1091~1094
静脉注射18F-FDG注射液后冲洗注射器对残留剂量及肝脏标准化摄取值的影响
Impact of syringe saline flush after injection of 18F-FDG on residual dose and standardized uptake value of liver
投稿时间:2019-01-12  修订日期:2019-05-28
DOI:10.13929/j.1003-3289.201901081
中文关键词:  氟脱氧葡萄糖F18  注射器  残留量  标准化摄取值  正电子发射体层摄影术
英文关键词:fludeoxyglucose F 18  syringes  residual dose  standardized uptake value  positron-emission tomography
基金项目:国家自然科学基金(81527805)。
作者单位E-mail
郝振亮 民航总医院放射科, 北京 100123  
王俊清 中国医学科学院北京协和医院核医学科, 北京 100730  
任超 中国医学科学院北京协和医院核医学科, 北京 100730  
赵晓斌 首都医科大学附属北京天坛医院核医学科, 北京 100070 flxzxb@163.com 
摘要点击次数: 1735
全文下载次数: 630
中文摘要:
      目的 探讨PET/CT检查时静脉注射18F-FDG注射液后冲洗注射器对放射性药物残留剂量以及肝脏标准化摄取值(SUV)的影响。方法 收集接受PET/CT检查的50例患者,根据注药方式分为对照组(n=25)和实验组(n=25)。采用23G头皮针建立静脉通路,注射18F-FDG注射液后,对照组直接用5 ml生理盐水冲洗管道;实验组先用1 ml生理盐水冲洗管道,然后用2 ml生理盐水冲洗注射器,最后用剩余2 ml再次冲洗管道。比较2组间18F-FDG注射后残留剂量以及肝脏SUV平均值(SUVmean)和SUV最大值(SUVmax)的差异。结果 实验组总残留剂量[(0.22±0.08)mCi]、注射器内残留剂量[(0.19±0.07)mCi]和静脉通道内残留剂量[(0.03±0.02)mCi]均小于对照组(P均<0.01)。实验组与对照组肝脏3个不同层面(第二肝门层面、门静脉左支层面、第一肝门层面)的SUVmean和SUVmax差异均无统计学意义(P均>0.05)。结论 冲洗注射器能减少18F-FDG注射液残留量。注射器内少量放射性药物残留尚不足以引起肝脏SUV变化,但进一步规范18F-FDG注射操作流程仍属必要。
英文摘要:
      Objective To investigate the impact of saline flush for syringe after 18F-FDG injection on the residual dose of 18F-FDG and the standardized uptake value (SUV) of liver during PET/CT examination. Methods A total of 50 patients who underwent PET/CT examination were enrolled and divided into control group (n=25) and experimental group (n=25) according to different injection methods. Device system of the vein passage was established with 23 gauge scalp needle. In control group, the intravenous line was directly flushed with 5 ml physiological saline after 18F-FDG injection, while in experimental group, firstly the intravenous line was flushed with 1 ml saline, then the syringe was flushed with 2 ml saline, finally the intravenous line was flushed again with the residual 2 ml saline. The residual dose of 18F-FDG and SUVmean and SUVmax of liver were compared between the two groups. Results The total residual dose ([0.22±0.08]mCi), syringe residual dose ([0.19±0.07]mCi) and intravenous channel residual dose ([0.03±0.02]mCi) in the experimental group were all lower than those in control group (all P<0.01). There was no significant difference of SUVmean nor SUVmax between experimental group and control group at 3 different levels of the liver (level of the second liver porta, level of the left portal vein and level of the first liver porta, all P>0.05). Conclusion Flushing the syringe can reduce residual dose of 18F-FDG injection. A small amount of radiopharmaceuticals retention in the syringe may not affect SUV for liver, but further standardization of the operation process of 18F-FDG injection is still necessary.
查看全文  查看/发表评论  下载PDF阅读器